JDB-LTHP, a 30 °C vacuum evaporator

Heat-pump vacuum evaporator for wastewater: it boils at 28–30 °C under −0.098 MPa, so the water leaves clean and the concentrate shrinks to a fraction you can still afford to ship out.

  • Evaporation rate5 to 500 L/h, 13 sizes
  • Evaporation temperature28 to 30 °C
  • Vacuum−0.098 MPa
  • Heat-transfer delta2 °C
  • Water recoveryup to 95%
  • TankSUS 316L
  • CompressorCopeland (US) or Bitzer (DE)
  • ControlsDanfoss and Faas components, PLC
  • Power1.2 to 160 kW across the range
  • Energy80 to 200 kWh per tonne of water
The JDB-LTHP low-temperature evaporator: stainless cabinet, vacuum chamber and control panel

How the water leaves

Waste water in on the left, clean water out on the right. The heat pump moves heat from the vapour side into the jacket, so the only energy going in is the compressor.

Process diagram of the JDB-LTHP: waste water enters the chamber, vapour condenses in the condenser, clean water leaves and the concentrate or crystals are discharged.

The unit, up close

As it ships: the 316L chamber, the vacuum column, the heat pump and the control panel.

J-Series solvent recovery machine, photograph 1
J-Series solvent recovery machine, photograph 2
J-Series solvent recovery machine, photograph 3