Power stays on until the vapour cools, no feeding or digging out under power, and the lid stays shut above 60 °C. The short version that belongs on the wall.

These are the instructions that ship with every machine. They are short on purpose: they have to be read at the machine, not in an office.
- Power stays on until the vapour temperature has dropped into the safe range. Cutting the supply early leaves solvent vapour in the tank.
- No feeding and no digging out residue while the machine is energised.
- The lid stays shut during heating, and while the heat-transfer oil is above 60 °C.
- Keep the lines clear. The condenser is cleaned daily.
- Change the heat-transfer oil every 1,000 operating hours, or every six months.
- Skip any of the above and the consequences are the operator's.
What we turn away
Materials carrying explosives, nitrate esters, nitroalkanes, organic peroxides, pyrophoric or water-reactive metals, or strong oxidizers are not processed at all. The full list sits in the previous entry of this section.
Waste of unknown composition, or without an SDS, is treated the same way until it has been identified.
Residue containing nitrocellulose stays wet, stays sealed, and goes to a licensed hazardous-waste facility.